MIL-PRF-83383E
TABLE VlII. Terminal strength forces.
Stud or screw
Tensile load
Design torque
Recommended
size (inch)
(pounds)
(inch-pounds)
installation torque
(inch-pounds)
.190
30
30
18
.250
30
60
36
FIGURE 4. Terminal strength test.