MIL-PRF-83383/4F
Power requirements and response time at minimum voltage:
Standby current drain and actuation current:
Test voltage: 28 ±0.5 V dc to TJS module, then 200 ±2 V line to line, 400 Hz, 3 phase ground
neutral to line terminal. Actuating current, 6.0 amperes dc and 11 amperes ac rms maximum.
Maximum operating time at minimum voltage:
Test voltage: 181 V ac rms maximum line-to-line, 3 phase.
Endurance:
Electrical:
5 to 25 amperes: 30,000 cycles resistive or inductive or motor load or lamp load.
35 to 50 amperes: 30, 000 cycles resistive or inductive or motor load or 25,000 cycles lamp load.
60 to 100 amperes: 30,000 cycles resistive or inductive load or 25,000 cycles motor load.
Interrupting capacities:
G - 3,600 amperes, single phase an 2,160 amperes, three phase.
H - 3,600 amperes, single phase and 2,160 amperes, three phase.
Other marking:
Current rating: See figure 1.
Line and load terminals: See figure 1.
Terminal junction system (TJS) module: See figure 3.
Position indication: See figure 1. Indication is provided by a lens over "open" and "closed" on red and
green background.
Part or Identifying Number (PIN): M83383/04- (dash number from table I) (e.g., M83383/04-01).