TABLE III. Operating voltage, frequency, and tripping-time delay delay (configuration 1). 1/
Tripping-time delay at 25C 2C (tripping time in seconds)
Time
delay
50 V dc
240 V ac, 60 Hz
240 V ac, 400 Hz
percent
K
L
M
N
P
R
S
rated
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
current
no trip
no trip
no trip
no trip
no trip
no trip
no trip
100
one hour
one hour
one hour
one hour
one hour
one hour
one hour
125
100
10
12
.5
120
10
18
1
N/A
N/A
N/A
N/A
N/A
N/A
150
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
60
6
5.8
.6
500
60
200
20
2.5
1.5
.13
20
3
1.6
.16
20
2.1
2
.2
160
20
400
2
2
.36
.29
.031
2.3
.3
.3
.04
4
.4
.35
.035
19
600
1
.13
.15
Inst
.1
.13
.17
Inst
.6
Inst
.125
Inst
3.5
.250
800
.6
Inst
.06
Inst
.6
Inst
.09
Inst
.06
Inst
.05
Inst
.5
.025
1,000
.29
Inst
.05
Inst
.29
Inst
.043
Inst
.045
Inst
.036
Inst
Inst
.043
1,800 2/
no trip
no trip
no trip
no trip
no trip
no trip
no trip
See footnotes at end of table IV.