MIL-PRF-83383/2F
Power requirements and response time at minimum voltage:
Standby current drain and actuation current:
Test voltage: 28 0.5 V dc to TJS module, then 115 2 V ac, 400 Hz to line terminal. Actuating
current, 3.5 amperes dc and 11 amperes ac rms maximum.
Maximum operating time at minimum voltage:
Test voltage: 18 V dc then 104 V ac rms, 400 Hz, maximum.
Endurance:
Electrical:
5 to 25 amperes: 50,000 cycles resistive or inductive or motor load or lamp load.
35 to 50 amperes: 50, 000 cycles resistive or inductive or motor load or 25,000 cycles lamp load.
60 to 100 amperes: 50,000 cycles resistive or inductive load or 25,000 cycles motor load.
Interrupting capacities:
A - 3,600 amperes.
B - 3,600 amperes.
C - 3,600 amperes.
D - 3,600 amperes.
Other marking:
Current rating: See figure 1.
Line and load terminals: See figure 1.
Terminal junction system (TJS) module: See figure 3.
Position indication: See figure 1. Indication is provided by a lens over "open" and "closed" on red and
green background.
Part or Identifying Number (PIN): M83383/02- (dash number from table I) (e.g., M83383/02-01).
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.