TABLE V. Operating voltage, frequency, and tripping-time delay (configuration 2). 1/
Tripping-time delay at 25°C ±2°C (tripping time in seconds)
50 V dc
240 V ac, 60 Hz
240 V ac, 400 Hz
Time
delay
percent
rated
K
L
M
N
P
R
S
current
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
no trip
no trip
no trip
no trip
no trip
no trip
no trip
100
one hour
one hour
one hour
one hour
one hour
one hour
one hour
N/A
N/A
N/A
N/A
N/A
N/A
0.7
12
10
120
0.5
6.5
7
60
125
40
400
0.5
8
5
70
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
150
9.5
150
0.15
1.9
2.1
25
0.13
3
2.2
20
0.13
1.2
0.6
10
200
1.9
19
0.02
0.4
0.4
5
0.03
1
0.3
3
0.031
0.5
0.15
2
400
Inst
7
Inst
0.25
Inst
2.4
Inst
0.3
Inst
2
Inst
0.25
Inst
1
600
Inst
0.4
Inst
0.1
Inst
1
Inst
0.15
Inst
0.8
Inst
0.1
Inst
0.5
800
Inst
0.043
Inst
0.05
Inst
0.1
Inst
0.1
Inst
0.25
Inst
Inst
Inst
0.1
1,000
1,800 2/
no trip
no trip
no trip
no trip
no trip
no trip
no trip
See footnotes at end of table VI.
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business